Non Cyanide Type Electroless Gold Plating Chemicals

- HGS-5400 is the electroless gold plating chemicals which is non-cyanide,very stable and long life. This electroless gold plating has good wire-bonding reliability.
Features
- Non-cyanide type electroless gold plating chemicals. Gold source is sodium gold sulfite.
- Plating at various gold thickness.
- Keeping long life by analyzing and replenishing ingredients.
- Plating on fine pattern of LTCC substrates by applying HGS-5500T pre-treatment in standard process.
Characteristics
| Items |
Conditions |
Units |
Characteristics |
| Gold concentration |
- |
g/L |
2.25 |
| pH |
- |
- |
7.5 |
| Treatment temperature |
Indirect method
( using double tank in hot water ) |
ºC |
65 |
| Gold appearance |
- |
- |
Light Yellow |
| Gold plating rate |
at 65ºC |
μm/h |
0.9 |
| Pull strength of wire-bonding |
Gold wire φ25μm |
g |
7~10 |
| Ball shear strength |
Ball diameter φ0.4mm |
g |
700~900 |
 |
Gold surface of HGS-5400 with SEM
(Gold plating rate 0.5μm;×10,000) |
Without HGS-5500T treatment With HGS-5500T treatment |
 |